Campbell-scientific OBS-3+ and OBS300 Suspended Solids and Turbidity M Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Campbell-scientific OBS-3+ and OBS300 Suspended Solids and Turbidity M. Campbell Scientific OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors Revision: 9/14 Copyright © 2008- 2014 Campbel

Strona 2

Table of Contents iv

Strona 3 - Limited Warranty

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 1. Introduction The OBS-3+ and OBS300 are submersible, turbidity sensors that use OBS® tec

Strona 4 - Assistance

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 4. Quickstart 4.1 Preparation for Use 1. Bench test the sensor to ensure that it function

Strona 5 - Precautions

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 3. When Short Cut opens, select New Program. 4. Select Datalogger Model and Scan Interva

Strona 6

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 5. Under the Available Sensors and Devices list, select the Sensors | Water | Quality fold

Strona 7

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 8. If LoggerNet, PC400, or PC200W is running on your PC, and the PC to datalogger connectio

Strona 8

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors Turbidity is caused by suspended and dissolved matter such as sediment, plankton, bacteria,

Strona 9

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 5-1. Components of the OBS-3+ (left) and orientation source beam and detector

Strona 10 - Table of Contents

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 6. Specifications Features: • Measures suspended solids and turbidity for up to 4000 NTU

Strona 11 - 3. Initial Inspection

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 7. Installation If you are programming your da

Strona 13

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 7.2 Mounting Considerations Schemes for mounting the OBS-3+ and OBS300 will vary with appli

Strona 14

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors TABLE 7-1. Connection to Campbell Scientific Dataloggers Color Description CR800, CR850

Strona 15 - 5. Overview

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 7.4 Datalogger Programming CRBasic and Edlog are included in our PC400 and LoggerNet Datalo

Strona 16 - 5.3 Design Details

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 7-2. Calibration certificate showing millivolt coefficients Curve Type Polynomial f

Strona 17 - 5.4 Measurement Details

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 7-3. Calibration certificate showing volts coefficients 8. Calibration 8.1 Turbid

Strona 18 - 6. Specifications

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors NTU value with a 2nd-order polynomial. This section explains how to do a turbidity calibrat

Strona 19 - 7. Installation

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors The NTU values of the standards will remain the same as long as the ratio of particle mass (

Strona 20 - 7.3 Wiring to Datalogger

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 8.1.2 Setup 1. Plug the test cable into the OBS sensor; connect the red and black leads to

Strona 21

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 8. Perform 2nd-order polynomial regressions on the calibration data to get the coefficients

Strona 22 - 7.5 Calibration Certificate

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors suspender after each addition of sediment for the determination of SSC by filtration and gra

Strona 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Strona 24 - 8. Calibration

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors see FIGURE 8-4. For the OBS300, mount the sensor so that the laser diode is submerged just

Strona 25 - Turbidity (NTU)

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 8. Add enough additional sediment to get one full increment of sediment, Wi ± 5%. Repeat s

Strona 26

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors TABLE 9-1. Troubleshooting Chart Fault Cause of Fault Remedy Fails finger wave test No po

Strona 27 - 8.1.3 Procedure

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 11. Factors that Affect Turbidity and Suspended-Sediment Measurements This section summariz

Strona 28 - 8.2 Sediment

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 11-2. The apparent change in turbidity resulting from disaggregation methods 11.2

Strona 29 - 8.2.3 In situ Calibration

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 0 20 40 60 80 100 120 140 160 180Scat t ering Angle0.010.11Relative Scattering IntensityCube

Strona 30

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 11-4. Response of an OBS sensor to a wide range of SSC 11.5 IR Reflectivity—Sedime

Strona 31 - 9. Troubleshooting

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors FIGURE 11-5. Infrared reflectivity of minerals as a function of 10-Munzell value 11.6 Wa

Strona 32 - 10. Maintenance

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors organic matter and interference from these materials can therefore be ignored most of the ti

Strona 33 - Sediment Measurements

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors 13. Terminology 110 Rule: 100 ppm of 100-μm suspended sand will scatter light with the same

Strona 34 - 11.3 Particle-Shape Effects

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strona 35 - Scat t ering Angle

OBS-3+ and OBS300 Suspended Solids and Turbidity Monitors sediment, plankton, bacteria and viruses, organic acids, and dyes. In general, as the conce

Strona 36

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement. • H

Strona 37 - 11.7 Bubbles and Plankton

Appendix A. Importing Short Cut Code 5. The program can now be edited, saved, and sent to the datalogger. 6. Import wiring information to the progr

Strona 38 - 12. References

Appendix B. Example Programs B.1 CRBasic Examples B.1.1 CR1000 Example Program Below is an example CR1000 program. The calibration values used in

Strona 39 - 13. Terminology

Appendix B. Example Programs 'the true NTU. Big particles can cause errors that would skew an average NTU = NTUX(11) 'Use the low

Strona 40

Appendix B. Example Programs For i = 1 To n 'n=10 in this case so ten measurements will be made for both the high and low 'in

Strona 41 - A.1.1 CRBasic Datalogger

Appendix B. Example Programs ;activate SW12V for turbidity probe, delay 3 seconds, then measure 1: Do (P86) 1: 48 Set Port 8 High 2: Excitat

Strona 42 - A.1.2 Edlog

Appendix B. Example Programs NTU = -0.20709 + (401.11*NTU_Volts) + (35.310*NTU_Volts^2) 6: End (P95) End Program B-5

Strona 43 - B.1 CRBasic Examples

Appendix B. Example Programs B-6

Strona 44

Appendix C. Electrical Connections Details FIGURE C-1 shows the contact numbers for the MCIL/MCBH-5 connectors and TABLE C-1 lists the electrical fu

Strona 45 - B.2 Edlog Example

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Strona 46

Appendix C. Electrical Connections Details TABLE C-1. Pin numbers, electrical functions and wire color codes for OBS sensor bulkhead connectors. MCB

Strona 47

Appendix D. Datalogger Connection to a Relay The CR10, CR7, CR510, and 21X dataloggers do not have a switched 12 V channel. Either the sensor can r

Strona 48

Appendix D. Datalogger Connection to a Relay D-2

Strona 50

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Strona 52

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strona 53

Table of Contents 10. Maintenance ..... 22 11. Factors that Affect Turbidity and Suspended-Se

Strona 54

Table of Contents 8-3. OBS-3+ (left) and OBS300 (right) in 500-NTU AMCO Clear® turbidity standard in 100-mm black polyethylene calibration cup ...

Komentarze do niniejszej Instrukcji

Brak uwag