Strona 1 - Version 1.0

for EnviroSCAN EnviroSMART Diviner 2000 ACCESS TUBE INSTALLATION GUIDE Version 1.0

Strona 2 - Diviner 2000

Site Selection © Sentek Pty Ltd Page 7 Cover crop and mulch Cover crops provide more competition for water, but reduce evaporation and facilitat

Strona 3 - Contents

Site Selection © Sentek Pty Ltd Page 8 The diagrams on the following pages show an example of how ‘factors that affect crop water use’ can be us

Strona 4 - About this manual

Site Selection © Sentek Pty Ltd Page 9 From this the requirements for soil improvements and amelioration are outlined: Once t

Strona 5

Site Selection © Sentek Pty Ltd Page 10 Overlaying all this information makes it possible to identify, within a property, areas (zones) that hav

Strona 6

Site Selection © Sentek Pty Ltd Page 11 In the example illustrated below, cans in the blue shaded area received above average water; th

Strona 7 - Climate

Site Selection © Sentek Pty Ltd Page 12 In addition, in drip irrigation, the slope needs to be taken into consideration, to account for movement

Strona 8

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 13 Installing access tubes for Diviner 2000, EnviroSCAN

Strona 9 - Cultural Management

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 14 Disclaimer: The access tubes, probes and sensors su

Strona 10 - Water Quality

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 15 The figure below shows preferential flow of water do

Strona 11 - Site Selection

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 16 Standard manual installation method Introduction The

Strona 12

Access Tube Installation Guide EnviroSCAN EnviroSMART Diviner 2000 All rights reserved. No part of this document may be reproduced, transc

Strona 13 - Micro scale zone selection

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 17 Toolkit items Item Part Number Standard Access T

Strona 14

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 18 1 x Nylon dolly 70205 1 x Heavy duty dolly 7

Strona 15 - Soil properties

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 19 To assemble the tripod at the site: 1. Attach the b

Strona 16 - EnviroSMART probes

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 20 Watch the bubble in the spirit level on the side of

Strona 17

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 21 4. Select the 47.0 mm regular auger head. Note: T

Strona 18

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 22 7. Disengage the metal “tooth” on the tripod by turn

Strona 19 - Introduction

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 23 depth has been reached. Note: If the access tube sp

Strona 20 - Toolkit items

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 24 16. Auger ahead of the access tube by approximately

Strona 21 - Installation procedure

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 25 20. When all pins are removed, carefully lift the tr

Strona 22

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 26 Step 4 – Cleaning the access tube The access tube mu

Strona 23 - To install the access tube

Access Tube Installation Guide Low Res Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page i Contents Access Tube Installation Guid

Strona 24

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 27 6. Change cotton cloths as required and continue wi

Strona 25

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 28 5. Place the Expandable Bung Tightening Tool over t

Strona 26

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 29 2. Take a silicon gun with a new nozzle and apply t

Strona 27

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 30 8. For EnviroSCAN and EnviroSMART probes, strip back

Strona 28

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 31 5. Insert the assembled auger into the tripod ensu

Strona 29 - To clean the tube

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 32 3. Fit the Auger Centralization Poly Guide over the

Strona 30

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 33 Gravelly soils If you encounter a layer of small sto

Strona 31 - To install the top cap

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 34 Stony Soils The standard manual installation method

Strona 32

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 35 Slurry Installation Method What are the different sl

Strona 33

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 36 Note: Slurry installations take some preparation ti

Strona 34 - Dry and heavy clay soil

Access Tube Installation Guide Low Res Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page 1 About this manual This guide describes

Strona 35

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 37 Additional items for difficult stony soils Item Pa

Strona 36 - Water tables

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 38 Installation procedure Step 1 – Glue in bottom stopp

Strona 37 - Stony Soils

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 39 Step 2 – Auger the hole To manually auger the access

Strona 38 - Slurry Installation Method

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 40 Hint: If you encounter difficulties augering throug

Strona 39 - Sentek access tube items

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 41 Step 3 – Make the slurry Slurry Recipe • 1 part gre

Strona 40 - Slurry Components

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 42 Step 4 – Insert the access tube To install the acces

Strona 41

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 43 Step 5 – Chip off excess slurry To tidy up around th

Strona 42 - Step 2 – Auger the hole

Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 44 6. Screw the cap back onto the top cap housing.

Strona 43

Removing access tubes © Sentek Pty Ltd Page 45 Removing Access Tubes Access tubes can be removed from a site when the site no longer requires mo

Strona 44 - Step 3 – Make the slurry

Removing access tubes © Sentek Pty Ltd Page 46 4. Use the Tommy Bars to tighten the T-Handle and Expandable bung tightening tool to the extensio

Strona 45

Introduction Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page 2 Introduction The Access Tube Installation Guide provides import

Strona 46

Removing access tubes © Sentek Pty Ltd Page 47 5. Place the hook of the steel cable from the tripod through the upper eye of the extraction too

Strona 47

Toolkit items © Sentek Pty Ltd Page 48 Toolkit Items Sentek access tube items Part No. 20510 Part No. 21010 Part No. 21510 Part No. 22010 1.0 me

Strona 48 - Removing Access Tubes

Toolkit items © Sentek Pty Ltd Page 49 Standard Access Tube Installation Kit Complete (Part No. 07000) Part A – Auger Kit (Part Number 07050)

Strona 49

Toolkit items © Sentek Pty Ltd Page 50 Part No. 70150 1 x Regular T-handle The T-handle is attached to the auger extension rods, which are a

Strona 50

Toolkit items © Sentek Pty Ltd Page 51 Part No. 70215 3 x Tripod anchor pins The 600 mm tripod anchor pins are used to fix the tripod in pla

Strona 51 - Toolkit Items

Toolkit items © Sentek Pty Ltd Page 52 Part No. 70030 Heavy Duty T-Handle The Heavy Duty T-Handle is a reinforced T-Handle that attaches to

Strona 52

Toolkit items © Sentek Pty Ltd Page 53 Part No. 70180 Access tube cutting tool The access tube cutting tool is a precision PVC pipe cut

Strona 53

Recommended Reading © Sentek Pty Ltd Page 54 Recommended Reading Brady, N.C., Weil, R.R., 1996, The Nature and Properties of Soils, 11th Editio

Strona 54

Site Selection © Sentek Pty Ltd Page 3 Site Selection The key to effective soil moisture monitoring is to select monitoring sites which truly re

Strona 55

Site Selection © Sentek Pty Ltd Page 4 Micro zone selection determines the position of access tubes in relation to the crop and irrigation syste

Strona 56

Site Selection © Sentek Pty Ltd Page 5 Notwithstanding the care taken to delineate macro zones, some variability in soil moisture levels is inev

Strona 57 - Recommended Reading

Site Selection © Sentek Pty Ltd Page 6 Organic Matter The presence of organic matter and humus increases the cation exchange capacity (CEC), wat

Komentarze do niniejszej Instrukcji