for EnviroSCAN EnviroSMART Diviner 2000 ACCESS TUBE INSTALLATION GUIDE Version 1.0
Site Selection © Sentek Pty Ltd Page 7 Cover crop and mulch Cover crops provide more competition for water, but reduce evaporation and facilitat
Site Selection © Sentek Pty Ltd Page 8 The diagrams on the following pages show an example of how ‘factors that affect crop water use’ can be us
Site Selection © Sentek Pty Ltd Page 9 From this the requirements for soil improvements and amelioration are outlined: Once t
Site Selection © Sentek Pty Ltd Page 10 Overlaying all this information makes it possible to identify, within a property, areas (zones) that hav
Site Selection © Sentek Pty Ltd Page 11 In the example illustrated below, cans in the blue shaded area received above average water; th
Site Selection © Sentek Pty Ltd Page 12 In addition, in drip irrigation, the slope needs to be taken into consideration, to account for movement
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 13 Installing access tubes for Diviner 2000, EnviroSCAN
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 14 Disclaimer: The access tubes, probes and sensors su
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 15 The figure below shows preferential flow of water do
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 16 Standard manual installation method Introduction The
Access Tube Installation Guide EnviroSCAN EnviroSMART Diviner 2000 All rights reserved. No part of this document may be reproduced, transc
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 17 Toolkit items Item Part Number Standard Access T
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 18 1 x Nylon dolly 70205 1 x Heavy duty dolly 7
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 19 To assemble the tripod at the site: 1. Attach the b
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 20 Watch the bubble in the spirit level on the side of
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 21 4. Select the 47.0 mm regular auger head. Note: T
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 22 7. Disengage the metal “tooth” on the tripod by turn
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 23 depth has been reached. Note: If the access tube sp
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 24 16. Auger ahead of the access tube by approximately
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 25 20. When all pins are removed, carefully lift the tr
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 26 Step 4 – Cleaning the access tube The access tube mu
Access Tube Installation Guide Low Res Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page i Contents Access Tube Installation Guid
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 27 6. Change cotton cloths as required and continue wi
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 28 5. Place the Expandable Bung Tightening Tool over t
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 29 2. Take a silicon gun with a new nozzle and apply t
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 30 8. For EnviroSCAN and EnviroSMART probes, strip back
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 31 5. Insert the assembled auger into the tripod ensu
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 32 3. Fit the Auger Centralization Poly Guide over the
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 33 Gravelly soils If you encounter a layer of small sto
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 34 Stony Soils The standard manual installation method
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 35 Slurry Installation Method What are the different sl
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 36 Note: Slurry installations take some preparation ti
Access Tube Installation Guide Low Res Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page 1 About this manual This guide describes
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 37 Additional items for difficult stony soils Item Pa
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 38 Installation procedure Step 1 – Glue in bottom stopp
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 39 Step 2 – Auger the hole To manually auger the access
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 40 Hint: If you encounter difficulties augering throug
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 41 Step 3 – Make the slurry Slurry Recipe • 1 part gre
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 42 Step 4 – Insert the access tube To install the acces
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 43 Step 5 – Chip off excess slurry To tidy up around th
Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes © Sentek Pty Ltd Page 44 6. Screw the cap back onto the top cap housing.
Removing access tubes © Sentek Pty Ltd Page 45 Removing Access Tubes Access tubes can be removed from a site when the site no longer requires mo
Removing access tubes © Sentek Pty Ltd Page 46 4. Use the Tommy Bars to tighten the T-Handle and Expandable bung tightening tool to the extensio
Introduction Copyright © 1991 – 2003 Sent ek Pt y Ltd All rights reserved Page 2 Introduction The Access Tube Installation Guide provides import
Removing access tubes © Sentek Pty Ltd Page 47 5. Place the hook of the steel cable from the tripod through the upper eye of the extraction too
Toolkit items © Sentek Pty Ltd Page 48 Toolkit Items Sentek access tube items Part No. 20510 Part No. 21010 Part No. 21510 Part No. 22010 1.0 me
Toolkit items © Sentek Pty Ltd Page 49 Standard Access Tube Installation Kit Complete (Part No. 07000) Part A – Auger Kit (Part Number 07050)
Toolkit items © Sentek Pty Ltd Page 50 Part No. 70150 1 x Regular T-handle The T-handle is attached to the auger extension rods, which are a
Toolkit items © Sentek Pty Ltd Page 51 Part No. 70215 3 x Tripod anchor pins The 600 mm tripod anchor pins are used to fix the tripod in pla
Toolkit items © Sentek Pty Ltd Page 52 Part No. 70030 Heavy Duty T-Handle The Heavy Duty T-Handle is a reinforced T-Handle that attaches to
Toolkit items © Sentek Pty Ltd Page 53 Part No. 70180 Access tube cutting tool The access tube cutting tool is a precision PVC pipe cut
Recommended Reading © Sentek Pty Ltd Page 54 Recommended Reading Brady, N.C., Weil, R.R., 1996, The Nature and Properties of Soils, 11th Editio
Site Selection © Sentek Pty Ltd Page 3 Site Selection The key to effective soil moisture monitoring is to select monitoring sites which truly re
Site Selection © Sentek Pty Ltd Page 4 Micro zone selection determines the position of access tubes in relation to the crop and irrigation syste
Site Selection © Sentek Pty Ltd Page 5 Notwithstanding the care taken to delineate macro zones, some variability in soil moisture levels is inev
Site Selection © Sentek Pty Ltd Page 6 Organic Matter The presence of organic matter and humus increases the cation exchange capacity (CEC), wat
Komentarze do niniejszej Instrukcji