Campbell-scientific Sentek EnviroSCAN EasyAG SDI-12 Manual v 3.4 Instrukcja Użytkownika Strona 28

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 30
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 27
EnviroSMART & EasyAG SDI-12 Probe Manual
Copyright © 1991 2003 Sentek Pty Ltd All rights reserved Page 23
Appendix A – Soil Moisture Management
What soil volume does the SDI-12 probe interface measure at a
single sensor?
At a single depth level, a sensor on the probe records volumetric water content from a soil volume
outside the access tube, which has a sphere of influence of:
10cm vertical height
5-10cm radial distance from the outer wall of the access tube
What are the water units?
If a calibrated sensor reads one(1) millimetre, there is one(1) millimetre of volumetric water content in a
soil volume 10cm deep.
Q. What does 1mm volumetric water content / 10cm soil depth mean?
A. You require one(1) litre of water to cover one(1) square meter (m²) to a soil depth of one(1)
millimetre.
Figure 9: Measurements using metric units
Przeglądanie stron 27
1 2 ... 23 24 25 26 27 28 29 30

Komentarze do niniejszej Instrukcji

Brak uwag