Appendix C. Exchanging Internal
Enclosure Mounting Bracket
C.1 Introduction
A replacement mounting bracket may be required for RDP500 units shipped
prior to August of 2010. The new bracket provides additional clearance
between the RDP500 enclosure and the lower access door of the rain gauge
housing.
C.2 Exchange Process
The equipment required for the exchange includes the items below.
(1) WRENCH 7/16” THIN-HEAD
(1) WRENCH 1/2”
(1) REPLACEMENT ENCLOSURE MOUNTING BRACKET
(1) FLATHEAD SCREWDRIVER
Use the 7/16” wrench to loosen the two bolts securing the RDP500 enclosure
to the rain gauge base. The two bolts are located at the bottom corners of the
RDP500 enclosure and can be accessed through the slot located along the
bottom corners of the RDP500 mounting bracket.