28: Z=X^Y (P47)
1: 9 -- X Loc [ ES1_WC_1 ]
2: 34 Y Loc [ RecipB ]
3: 9 -- Z Loc [ ES1_WC_1 ]
29: End (P95) ;End If
30: End (P95) ;End If
31: End (P95) ;Next Loop
;Measure Rain
32: Pulse (P3)
1: 1 Reps
2: 1 Pulse Channel 1
3: 2 Switch Closure, All Counts
4: 25 Loc [ Rain_mm ]
5: .1 Mult
6: 0 Offset
;Input irrigation events manually in Irrimax, 0 must be written to data file
33: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 26 Z Loc [ Irrig_mm ]
;Output SF & VIC Data to Storage
34: Do (P86)
1: 10 Set Output Flag High (Flag 0)
35: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
36: Real Time (P77) ;Midnight = 0000 required by Irrimax Software
1: 1110 Year,Day,Hour/Minute (midnight = 0000)
37: Sample (P70)
1: 8 Reps
2: 1 Loc [ ES1_SF_1 ]
38: Sample (P70)
1: 8 Reps
2: 17 Loc [ ES1_VIC_1 ]
39: Totalize (P72)
1: 1 Reps
2: 25 Loc [ Rain_mm ]
12