Campbell Scientific CS512
Oxyguard Type III
Dissolved Oxygen Probe
Revision: 12/06
Copyright © 2001-2006
Campbell Scientific, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Dissolved Oxygen Probe

Campbell Scientific CS512 Oxyguard Type IIIDissolved Oxygen ProbeRevision: 12/06Copyright © 2001-2006Campbell Scientific, Inc.

Strona 2 - Warranty and Assistance

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 6 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculat

Strona 3 - CS512 Table of Contents

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of th

Strona 4 - Examples

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8 EXAMPLE 8. Sample Program using P86 and P22 Instructions 45: Do (P86) 1: 41

Strona 5 - 1. General Information

A-1 Appendix A. Dissolved Oxygen in Fresh Water Table

Strona 6 - 2. Specifications

Appendix A. Dissolved Oxygen in Fresh Water Table A-2

Strona 7 - 4. Optional Agitator

This is a blank page.

Strona 8 - 6. Wiring

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Strona 9 - 7. Programming

Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materi

Strona 10 - 8. Calibration

i CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab f

Strona 11 - 10. Agitator Control

CS512 Table of Contents ii Examples 1. Sample Program using P1... 5 2. Sample

Strona 12

1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system.

Strona 13 - Fresh Water Table

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2 2. Specifications Principle of Measurement: Membrane covered galvanic oxygen pr

Strona 14

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3 3. Optional Probe Accessories PT4-L — Agitator for stagnant conditions 18026 — D

Strona 15 - This is a blank page

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 4 FIGURE 4-2. CS512 with PT4 Agitator Optional Repeat Cycle Timer for Agitators:

Strona 16

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 5 7. Programming In the CR510, CR10X, and CR23X datalogger, Instruction P1 or P2 c