Podsumowanie treści

Strona 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL Model 109 Temperature Probe Revision: 9/14 Copyright © 1983- 2014 Campbell Scientific, Inc.

Strona 2

Model 109 Temperature Probe 2. The Short Cut installation should place an icon on the desktop of your computer. To open Short Cut, click on this ico

Strona 3 - Limited Warranty

Model 109 Temperature Probe 5. Under the Available Sensors and Devices list, select the Sensors folder, then select the Temperature sub-folder. Sele

Strona 4 - Assistance

Model 109 Temperature Probe 7. Select any other sensors you have, and then finish the remaining Short Cut steps to complete the program. The remaini

Strona 5 - Precautions

Model 109 Temperature Probe Steinhart-Hart Linearization Error: ≤ 0.03 °C (–50 to 70 °C) Probe Weight and Dimensions Weight with 10 ft cable:

Strona 6

Model 109 Temperature Probe FIGURE 6-2. Steinhart-Hart linearization error 7. Installation If you are programming your datalogger with Short Cut, s

Strona 7 - Table of Contents

Model 109 Temperature Probe 7.2 Datalogger Programming Short Cut is the best source for up-to-date datalogger programming code. Programming code is

Strona 8 - Figures

Model 109 Temperature Probe 7.3 Air Temperature Installation For air temperature measurements, locate probes over an open level area at least 9 m (EP

Strona 9 - Model 109 Temperature Probe

Model 109 Temperature Probe FIGURE 7-2. 109 and 41303-5A Radiation Shield on a CM200 Series Crossarm The 109 is held in the 41303-5A radiation shiel

Strona 10

Model 109 Temperature Probe 8. Operation 8.1 Sensor Schematic FIGURE 8-1. 109 Thermistor Probe Schematic 8.2 Measurement and Output Linearization

Strona 11

Model 109 Temperature Probe 8.3 Electrically Noisy Environments EMF noise emanating from the ac mains power grid can be a significant source of measu

Strona 13

Model 109 Temperature Probe Symptom: Incorrect temperature is reported. Verify the Mult and Offset arguments in Therm109() are correct for the desire

Strona 14 - 7. Installation

Appendix A. Importing Short Cut Code Into CRBasic Editor This tutorial shows: • How to import a Short Cut program into a program editor for additio

Strona 15 - 7.2 Datalogger Programming

Appendix A. Importing Short Cut Code Into CRBasic Editor A-2

Strona 16

Appendix B. Example Programs The following example can be used directly with CR200(X) series dataloggers. 'Program measures one 109 temperature

Strona 17

Appendix B. Example Programs BeginProg Scan(1,Sec,1,0) 'Measure the temperature Therm109(T109_C,1,1,Vx1,0,_60Hz,1.0,0.0) 'Cal

Strona 18 - 8. Operation

Appendix C. Thermistor Resistance and Temperature TABLE C-1. 109 Thermistor Resistance and Temperature1 Actual Temperature (°C) 10K3A1iA Thermistor

Strona 19 - 9.1 Troubleshooting

Appendix C. Thermistor Resistance and Temperature 4 26687 4.00 5 25395 5.00 6 24172 6.00 7 23016 7.00 8 21921 8.00 9 20885 9.00 10 19903 10.00 11 189

Strona 20 - 9.2 Maintenance

Appendix C. Thermistor Resistance and Temperature 60 2487 60.00 61 2399 61.00 62 2315 62.00 63 2234 63.01 64 2157 64.00 65 2082 65.00 66 2011 66.00 6

Strona 21 - Into CRBasic Editor

Appendix C. Thermistor Resistance and Temperature C-4

Strona 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Strona 24

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Strona 25

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strona 26

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Strona 28

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strona 29

Table of Contents Figures 6-1. Worst case probe and measurement errors .... 5 6-2. Steinhart-Hart linearizatio

Strona 30

Model 109 Temperature Probe 1. Introduction The 109 Temperature Probe uses a thermistor to measure temperature in air, soil, and water. It is compa

Komentarze do niniejszej Instrukcji

Brak uwag