Campbell-scientific CS470/CS471 Compact Bubbler System Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Campbell-scientific CS470/CS471 Compact Bubbler System. Campbell Scientific CS470/CS471 Compact Bubbler System User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - INSTRUCTION MANUAL

INSTRUCTION MANUAL CS470/CS471 Compact Bubbler System Revision: 7/14 Copyright © 2009- 2014 Campbell Scientific, Inc.

Strona 2

Table of Contents iv

Strona 3 - Limited Warranty

CS470/CS471 Compact Bubbler System 1. Introduction The CS470 and CS471 are designed for general liquid level measurements. They use SDI-12 or RS-23

Strona 4 - Assistance

CS470/CS471 Compact Bubbler System 3.1 Shipping Kit and Accessories 3.1.1 Shipping Kit The CS470/CS471 ships with: • (1) Installation Kit (top DIN

Strona 5 - Precautions

CS470/CS471 Compact Bubbler System 3. When Short Cut opens, select New Program. 4. Select Datalogger Model and Scan Interval (60 second or higher

Strona 6

CS470/CS471 Compact Bubbler System 5. Under the Available Sensors and Devices list, select the Sensors | Generic Measurements folder. Select SDI-12

Strona 7

CS470/CS471 Compact Bubbler System 7. Select any other sensors you have, then finish the remaining Short Cut steps to complete the program. The rema

Strona 8

CS470/CS471 Compact Bubbler System • Does not use pressurized nitrogen tank — requiring less frequent attendance • Existing tubes can be used • Com

Strona 9

CS470/CS471 Compact Bubbler System 7.1 DIP Switch Settings The default DIP switch settings are shown in TABLE 7-1. The default settings support SDI

Strona 10 - Table of Contents

CS470/CS471 Compact Bubbler System For optimal measurement results, the bubble chamber should be horizontal and aligned in the direction of water flow

Strona 11 - 3. Initial Inspection

CS470/CS471 Compact Bubbler System 7.4 Connect Tubing to the CS470/CS471 1. Cut the bubble tube at a 90° angle with a sharp knife (not scissors). 2

Strona 13

CS470/CS471 Compact Bubbler System FIGURE 7-2. Bubble Chamber Installation 2. Fasten the conduit in place 3. Attach an elbow or tee joint at the

Strona 14

CS470/CS471 Compact Bubbler System FIGURE 7-3. Connection of the Bubble Tube 7. Install the NPT adapter on the end of the elbow or tee joint. 8.

Strona 15 - 6. Specifications

CS470/CS471 Compact Bubbler System measuring tube for the required time period. The purge function can also be activated via an SDI-12 command. Pres

Strona 16 - 7. Installation

CS470/CS471 Compact Bubbler System FIGURE 7-5. CS470/CS471 Screw Terminals TABLE 7-2. Datalogger Wiring Terminal Terminal Number Function C

Strona 17 - 7.1 DIP Switch Settings

CS470/CS471 Compact Bubbler System 7.8 Programming Short Cut is the best source for up-to-date datalogger programming code. Programming code is need

Strona 18

CS470/CS471 Compact Bubbler System 1. Choose Edit/Insert Block. 2. After the Insert Block dialog box appears, type in a base name for the input loc

Strona 19

CS470/CS471 Compact Bubbler System • Use low capacitance, low resistance, screened cable (as fitted by Campbell Scientific) to reach distances of sev

Strona 20

CS470/CS471 Compact Bubbler System 9.1 Replacing Tubing 1. Untighten the nut securing the tubing to the hose connection. 2. Pull out tubing. 3. Un

Strona 21 - 7.6 Purging Function

CS470/CS471 Compact Bubbler System Any error states arising can be displayed as follows: Press pump membrane button briefly (< 1 sec). The LED lig

Strona 22 - 7.7 Wiring

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement. • H

Strona 23

Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service

Strona 24 - 7.8 Programming

Appendix A. Importing Short Cut Code 6. Import wiring information to the program by opening the associated .DEF file. Copy and paste the section be

Strona 25 - 8. Operation

Appendix B. Example Programs B.1 CRBasic Programs B.1.1 Example CR200(X) Program 'CR200 Series 'Declare the variable for the water leve

Strona 26 - 9. Maintenance

Appendix B. Example Programs B.1.2 Example CR1000 Program 'CR1000 Series Datalogger 'Declare the variable for the water level measurement

Strona 27 - 10. Troubleshooting

Appendix B. Example Programs B.2 Edlog Program Below is a portion of a CR10X program that measures the CS470/CS471. The instructions below do not st

Strona 28

Appendix B. Example Programs B-4

Strona 29 - A.1.1 CRBasic Datalogger

Appendix C. 4 to 20 mA Operation The load resistance connected to the CS470/CS471 must not exceed a specific maximum value. This value depends on t

Strona 30 - A.1.2 Edlog

Appendix C. 4 to 20 mA Operation C.1 Setting Operating Parameters using DIP Switches The following 4 to 20 mA operating parameters can be set with D

Strona 31 - B.1 CRBasic Programs

Appendix D. SDI-12 Sensor Support D.1 SDI-12 Command Basics SDI-12 commands have three components: Sensor address (a) – a single character, and is

Strona 32

Appendix D. SDI-12 Sensor Support D.1.3 Send Identification Command (aI!) Sensor identifiers are requested by issuing command aI!. The reply is def

Strona 33 - B.2 Edlog Program

Appendix D. SDI-12 Sensor Support TABLE D-2. Send Data Return Values SDI-12 Command Number of Values Returned Values Returned D! 7 Level [m],

Strona 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Strona 35

Appendix D. SDI-12 Sensor Support 4. Press the <enter> key until the datalogger responds with the CR2XX> prompt. At the CR2XX> prompt,

Strona 36 - Switches

Appendix D. SDI-12 Sensor Support In that case, simply enter the command SDI12 again, press <enter>, and key in the correct control port number

Strona 37 - D.1 SDI-12 Command Basics

Appendix D. SDI-12 Sensor Support 7. To query the CS470/CS471 for its current SDI-12 address, enter the command ?!. The CS470/CS471 will respond wi

Strona 38

Appendix D. SDI-12 Sensor Support D.3 Advanced SDI-12 Commands All advanced SDI-12 commands begin with O (the letter not zero). TABLE D-3. Advanced

Strona 39 - D.2 SDI-12 Transparent Mode

Appendix D. SDI-12 Sensor Support 0.003086 m/s2 for each kilometer above sea level. With the following formula the local gravitational constant g in

Strona 41

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Strona 42

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Strona 44

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Strona 45

Table of Contents Appendices A. Importing Short Cut Code ... A-1 A.1 Importing Short Cut Code into a Program Edit

Strona 46

Table of Contents 10-1. Status LED ....................... 17 D-1. CS470/CS471 SDI

Komentarze do niniejszej Instrukcji

Brak uwag