Campbell-scientific CS700 Tipping Bucket Rain Gage and CS700H Heated R Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Campbell-scientific CS700 Tipping Bucket Rain Gage and CS700H Heated R. Campbell Scientific CS700 Tipping Bucket Rain Gage and CS700H Heated Rain Gage User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Revision: 5/11

CS700 Tipping Bucket Rain Gageand CS700H Heated Rain GageRevision: 5/11Copyright © 1995-2011Campbell Scientific, Inc.

Strona 2 - Warranty and Assistance

CS700 and CS700H Rain Gage FIGURE 3-1. CM240 Mounting Bracket 24"08"FIGURE 3-2. Typical Rain Gage Installation 6

Strona 3

CS700 and CS700H Rain Gage 3.5”1.5”24”14” FIGURE 3-3. Pedestal Base Options 3.3 Leveling Level the rain gage after mounting it. To l

Strona 4 - List of Tables

CS700 and CS700H Rain Gage Funnel Tipping Bucket Assembly Housing Bullseye Level Base Base Screw FIGURE 3-4. Main Components of the CS700 3.4 CS7

Strona 5 - CS700 and CS700H Rain Gage

CS700 and CS700H Rain Gage 4.1 CS700 Connections The CS700 is typically wired to a datalogger’s pulse channel (see Table 4-1). TABLE 4-1. CS700 Wiri

Strona 6 - 2. Specifications

CS700 and CS700H Rain Gage 4.2 CS700H Heated Rain Gage Connections The CS700H sensor cable can be wired to the datalogger’s pulse channels (see Table

Strona 7 - 2.1 Heated Rain Gage

CS700 and CS700H Rain Gage The power cable is wired to the power supply (see Table 4-5). Figure 4-2 shows the terminals for connecting the power cabl

Strona 8

CS700 and CS700H Rain Gage 5. Datalogger Programming This section is for users who write their own datalogger programs. A datalogger program to meas

Strona 9 - 3. Installation

CS700 and CS700H Rain Gage 5.1.1.2 CR200(X) Series Pulse Channel Example 'CR200 Series 'CS700 program 'Declare Variables and Units Pu

Strona 10 - 08"

CS700 and CS700H Rain Gage 3: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 101 Array ID 4: Real Time (P77) 1: 1220

Strona 11 - 3.3 Leveling

CS700 and CS700H Rain Gage 5.1.2.2 CR200(X) Series Control Port Example 'CR200 ' A 20 kOhm pull up resistor is required to read a switch

Strona 12 - 4. Wiring

Warranty and Assistance PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from def

Strona 13 - 4.1 CS700 Connections

CS700 and CS700H Rain Gage 5: Sample (P70) 1: 1 Reps 2: 1 Loc [ Rain_mm ] *Table 2 Program 01: 0.0000 Execution Interval (seconds)

Strona 14

CS700 and CS700H Rain Gage Units BattV = Volts Units CH700HA =inch Units CH700HB =inch 'Define Data Tables DataTable(OneMin,True,-1) DataInter

Strona 15

CS700 and CS700H Rain Gage 6. Troubleshooting 6.1 Precipitation Symptom: No Precipitation 1. Check that the sensor is wired to the Pulse Channel s

Strona 16 - 5. Datalogger Programming

CS700 and CS700H Rain Gage To access the above components, dismantle the CS700 using the following procedure: 1. Remove the housing assembly from the

Strona 17

CS700 and CS700H Rain Gage 2. Separate the filter/siphon assembly from the funnel by pushing the filter while pulling the siphon (see Figure 7-2). Do

Strona 18

CS700 and CS700H Rain Gage 3. Disassemble the filter/siphon assembly by doing the following (see Figure 7-3): (a) Unscrew nut (b) Lightly press stem

Strona 19

CS700 and CS700H Rain Gage 7.2 Reassembling the CS700 1. Screw cap on stem, finger tighten only (see Figure 7-3). 2. Push stem into siphon body (se

Strona 20 - 5.2 CS700H Programming

CS700 and CS700H Rain Gage 8. Calibration The sensor is factory calibrated; recalibration is not required unless damage has occurred or the adjustmen

Strona 21

CS700 and CS700H Rain Gage 24

Strona 22 - 6. Troubleshooting

Appendix A. CS700H Operation Factory settings have been set to adequately measure precipitation during cold precipitation events. Changing these set

Strona 23

CS700 and CS700H Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookma

Strona 24

Appendix A. CS700H Operation When the CS700H is “not Active” the status LED flashes every 1.5 seconds. When the ambient temperature sensor detects th

Strona 25

Appendix A. CS700H Operation When snow is last detected, a timer is left running, to keep the heater cycling so that any snow built up on the funnel

Strona 26 - 7.2 Reassembling the CS700

Appendix A. CS700H Operation A.3 Status LED The Status LED, within the ambient temperature sensor probe, flashes to indicate the mode that the CS700

Strona 27 - 8. Calibration

Appendix A. CS700H Operation TABLE A-3. Snow Sensor Power Options Mode (X20 command) Snow Enabled X22 command Description 0 Snow sensor doesn’t

Strona 28

Appendix A. CS700H Operation TABLE A-4. SDI-12 V1.2 COMPLIANT COMMAND SET – Go to www.sdi-12.org Name Command Response Break Continuous spacing

Strona 29

Appendix A. CS700H Operation Notes: (1) Identification has the following syntax: a12HydrServTBHeat4.112345<CR><LF> -- ------------

Strona 30

Appendix A. CS700H Operation TABLE A-5. Special X Commands User ID aX04! aX04+12345! – X04 Command Get the transducer ID using the aD0! Command Set

Strona 31 - A.2 External Control

Appendix A. CS700H Operation Cycle Enable aX29! aX29+0! aX29+1! – X29 Command (Only operates if “External Control” set to 1) Get the Cycle Enable sta

Strona 32 - A.4 Snow Sensor

Appendix A. CS700H Operation A.5.2 Operating Modes The CS700H can be put into Automatic or Manual Operation Modes. Table A-6 describes how the mode

Strona 33 - A.5 SDI-12 Interface

Appendix A. CS700H Operation A.5.3 Command Examples For the following examples, the SDI-12 address is set to “0”. <CR> = Carriage Return and &

Strona 34

CS700 and CS700H Table of Contents ii Appendix A. CS700H Operation... A-1 A.1 High Power Operation .

Strona 35 - A.5.1 Special – X Commands

Appendix A. CS700H Operation A-12

Strona 37

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Strona 38 - A.5.2 Operating Modes

CS700 and CS700H Rain Gage 1. General Description The CS700 tipping bucket rain gage is manufactured by Hydrological Services Pty. Ltd. (Model TB-3),

Strona 39 - A.5.3 Command Examples

CS700 and CS700H Rain Gage FIGURE 1-1. The CS700 (left) and CS700H (right). 2. Specifications Orifice Diameter: 7.87 in (200 mm) Measureme

Strona 40

CS700 and CS700H Rain Gage 2.1 Heated Rain Gage Snow Sensor and Heater Operating Temperature Range: -20° to +5°C Output: SDI-12 Voltage Requiremen

Strona 41

CS700 and CS700H Rain Gage 2.1.1 Phoenix Contact Power Supply (AC option only) Model Name: Quint-PS/1AC/24DC/10 Input data Nominal input voltage:

Strona 42

CS700 and CS700H Rain Gage General data Width: 2.4 in. (60 mm) Height: 5.1 in. (130 mm) Depth: 4.9 in. (125 mm) Weight: 2.4 lb. (1.1 kg) Efficie

Komentarze do niniejszej Instrukcji