INSTRUCTION MANUAL CS451/CS456 Submersible Pressure Transducer Revision: 7/14 Copyright © 2009- 2014 Campbell Scientific,
Table of Contents iv
CS451/CS456 Submersible Pressure Transducer 1. Introduction The CS451/CS456 Submersible Pressure Transducer provides pressure and temperature measur
CS451/CS456 Submersible Pressure Transducer 4. Quickstart Short Cut is an easy way to program your datalogger to measure the sensor and assign datalo
CS451/CS456 Submersible Pressure Transducer 4. Select Datalogger Model and Scan Interval (60 second or higher scan interval is recommended). Click N
CS451/CS456 Submersible Pressure Transducer 6. Under the Available Sensors and Devices list, select the Sensors | Water | Level & Flow folder. S
CS451/CS456 Submersible Pressure Transducer 8. Select any other sensors you have, then finish the remaining Short Cut steps to complete the program.
CS451/CS456 Submersible Pressure Transducer FIGURE 5-1. CS451 nose cone options 6. Specifications Features: • Output acceptable for recordin
CS451/CS456 Submersible Pressure Transducer Measurement Ranges: Pressure (psig) Pressure (kPa) Depth of fresh water 0 to 2.9 0 to 20 0 to 2 m (6.7
CS451/CS456 Submersible Pressure Transducer Air Gap Standard and weighted nose cone: 0.653 cm (0.257 in) NPT fitting: 2.72 cm (1.07 in) Wei
CS451/CS456 Submersible Pressure Transducer 7.1.3 Appropriate Water Depth The CS451/CS456 must be installed below the water at a fixed depth. This d
CS451/CS456 Submersible Pressure Transducer the cable. If installing in a well, fasten the cable to the well head. Wrap the cable ties around the ca
CS451/CS456 Submersible Pressure Transducer For example, if the correct elevation of the water, as measured by a staff gauge or other measurement devi
CS451/CS456 Submersible Pressure Transducer 7.3.3 A150/CWS900 The A150 desiccated case allows the CS451/CS456 to be connected to the CWS900 wireless
CS451/CS456 Submersible Pressure Transducer When using a CR200(X), the SDI12Recorder() instruction has the following syntax: SDI12Recorder(Destinatio
CS451/CS456 Submersible Pressure Transducer 8.1.1 PC Connection Using the A200 The A200 or another device is required to connect the CS451/CS456 to a
CS451/CS456 Submersible Pressure Transducer 8.1.1.3 Powering the Sensor The A200 provides power to the sensor when it is connected to a PC’s USB port
CS451/CS456 Submersible Pressure Transducer FIGURE 8-2. Connect screen There are three settings that can be changed: SDI-12 address, Pressure/Level
CS451/CS456 Submersible Pressure Transducer TABLE 8-3. SDI-12 Commands SDI-12 Command Command Function Values Returned aM! Configured settings Pr
CS451/CS456 Submersible Pressure Transducer Periodic evaluation of the desiccant is vital for keeping the vent tube dry. The CS451/CS456 ships with t
CS451/CS456 Submersible Pressure Transducer Problem: Transducer appears to be operating properly but data shows a periodic or cyclic fluctuation not a
Limited Warranty “Products manufactured by CSI are warranted by CSI to be free from defects in materials and workmanship under normal use and service
CS451/CS456 Submersible Pressure Transducer 20
Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement • Ho
Appendix A. Importing Short Cut Code 5. The program can now be edited, saved, and sent to the datalogger. 6. Import wiring information to the progr
Appendix B. Example Programs B.1 CRBasic Programs B.1.1 Example Program for CR200(X)-Series Datalogger 'CR200(X) Series 'Declare the va
Appendix B. Example Programs B.1.2 Example Program for CR1000 Datalogger 'CR1000 Series Datalogger 'Declare the variable for the water le
Appendix B. Example Programs B.2 Example Program for CR10(X) Dataloggers Below is a portion of a CR10X program that measures the CS451/CS456. The i
Appendix B. Example Programs B-4
Appendix C. Calibration Certificate Each CS451/CS456 has been calibrated to meet printed accuracy specification at multiple temperature and pressure
Appendix C. Calibration Certificate C-2
Appendix D. SDI-12 Sensor Support D.1 SDI-12 Command Basics SDI-12 commands have three components: Sensor address (a) – a single character, and is
Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing
Appendix D. SDI-12 Sensor Support D.1.3 Send Identification Command (aI!) Sensor identifiers are requested by issuing command aI!. The reply is def
Appendix D. SDI-12 Sensor Support TABLE D-2. SDI-12 Commands SDI-12 Command Command Function Values Returned aD! Configured settings Pressure/Le
Appendix D. SDI-12 Sensor Support 3. Click on the Open Terminal button. 4. Press the <enter> key until the datalogger responds with the CR2X
Appendix D. SDI-12 Sensor Support characters are typed within 60 seconds, then the mode is exited. In that case, simply enter the command SDI12 agai
Appendix D. SDI-12 Sensor Support and valid entries for pp (pressure/level) are: 0 = psig 1 = kPa 2 = bar 3 = feet 4 = meter 5 = inch 6 = millimeter
Appendix E. RS-232 Connection Via PC Terminal Software PC terminal software can be used to communicate with the CS451/CS456 via the RS-232 communica
Appendix E. RS-232 Connection Via PC Terminal Software FIGURE E-1. Terminal Emulator TABLE E-2. RS-232 Terminal Commands Terminal Commands Values
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe
Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO
Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec
Table of Contents 9. Maintenance ..... 17 9.1 Every Visit ...
Table of Contents Tables 7-1. SDI-12 Wiring ..................... 11 7-2. RS-232 Wirin