Campbell-scientific CR10X Measurement and Control System Instrukcja Użytkownika Strona 329

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 362
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 328
Section 12. Program Control Instructions
12-3
Stand Alone
Datalogger
SendGetData P190 Wireless Sensor P193
Radio Settings
Radio address, net address, and hop sequence must be the same in all CR2xxs
and RF400s
in the network. Because only one header length can be set for a
radio, only one power cycling interval should be used in network; i.e., do not
mix 8 second and 1 second interval radio power cycling. RF on (no cycling) is
specified where necessary below.
CR205
Power Mode and
Header
Select power mode for
appro
p
riate response
time and current drain.
Select power mode for
appro
priate response
time and current drain.
Header must match
called s
t
ation’s cycle.
NO HEADER.
RfpinEn (lowest power)
o
r
to allow communi-
cation with computer for
checking station, down-
loading program:
RF8_Sec or RF1_sec.
RF400 on CR10X
or CR23X
Router, if used, must
se
nd appropriate header
Router, if used, must
send appropriate header
RF on, header to match
CR205 setting to allow
contacting CR205
Beacon Interval
0 0 0
RF400 on computer
RF on, header t
o match
neighbors’ settings
RF on, header to match
neighbors’ settings
RF on, header to match
neighbors’ settings
LoggerNet Settings
When RF400 with direct
access to
network is
connected to computer.
For each datalogger:
Com
-
PbusPort
-logger
For each datalogger
w
i
th stored data:
Com
-
P
busPort
-logger
For each master
dat
al
ogger:
Com
-
P
busPort
-logger
PakBus Get/Send Locations (P190)
A program control instruction that sends data to or retrieves data from another
datalogger in a PakBus network. This instruction can also be used to issue
commands to Modbus devices, where the datalogger acts as a Modbus master.
1: PakBus - Get/Send Locations (P190)
1: 00 Port
2: 0000 Address
3: 00 Command
4: 0000 Security
5: 0000 Remote Loc/Coil/Register
6: 0000 Swath
7: 0000 Local Loc [ ______________ ]
8: 0000 Result Code Loc [ ______________ ]
Przeglądanie stron 328