BlackGlobe Temperature Sensor for Heat Stress
Thermistor Interchangeability Limits
T
error
_therm_pos
T
error
_therm_neg
0
T
0.3
0.25
0.2
0.15
0.1
0.05
-0.05
-0.1
-0.15
-0.2
-0.25
-0.3
-5 10 25 40 55 70 85 100
FIGURE 5-2. Thermistor interchangeability limits
6. Installation
6.1 Siting
The BlackGlobe must be mounted in a location that will not be shadowed and
is representative of the environmental conditions to be measured.
6.2 Assembly and Mounting
Tools required for installing on a tripod or tower:
Adjustable end wrench or 7/16 in. and 1/2 in. open end wrench
Small screwdriver provided with the datalogger
Small pair of diagonal-cutting pliers
UV resistant cable ties provided with the BlackGlobe
6.2.1 Mounting the BlackGlobe on the Mounting Arm
The BlackGlobe and mounting kit (pn 29956) requires some assembly before
installation. The mounting kit comes with (see Figure 6.1):
Mounting arm
Mounting bolt
Two lock washers
Two nuts
Two pipe clamps (not used when mounted to a horizontal pipe cross
arm)
U-bolt with associated nuts and washers