7.3 Wiring
The 014A is typically connected to a datalogger’s pulse port (see TABLE 7-1).
TABLE 7-1. Connections to Campbell Scientific Dataloggers
Pulse Channels
Color
Wire Label
CR800
CR850
CR5000
CR3000
CR1000
CR9000X
CR510
CR500
CR10(X)
21X
CR7
CR23X
CR200(X)
Black Signal Pulse Pulse Pulse P_SW
White Signal Reference
G
Clear Shield
G
A control port may also be used to measure the 014A. With this option, the
white wire is connected to the 5 V terminal. Please note that the control port
method cannot be used with a CR200(X), CR500, CR510, CR7, 21X, or CR10
datalogger.
TABLE 7-2. Connections to Campbell Scientific Dataloggers
Control Ports
Color
Wire Label
CR800
CR850
CR5000
CR3000
CR1000
CR9000X
CR10X
CR23X
Black Signal C1-C8 C6-C8 C5-C8
White Signal Reference 5 V 5 V 5 V
Clear Shield
G
7.4 Programming
Short Cut is the best source for up-to-date datalogger programming code.
Programming code is needed,
when creating a program for a new datalogger installation.
when adding sensors to an existing datalogger program.
If your data acquisition requirements are simple and you are connecting the
sensor to a pulse port, you can probably create and maintain a datalogger
program exclusively with Short Cut. If your data acquisition needs are more
complex, the files that Short Cut creates are a great source for programming
code to start a new program or add to an existing custom program.