PakBus Networking GuideRevision: 10/08Copyright © 2004-2008Campbell Scientific, Inc.
PakBus Networking Guide 3.3 Routers A router is a PakBus device that can accept a packet and forward it toward its ultimate network destination. Rou
PakBus Networking Guide paths and possibly using marginal routes of communication. The PakBus address and the communication interface of the neighbor
PakBus Networking Guide 3.6 Concurrent Communication The packets in PakBus networking are small and the communication links are only active for a sho
PakBus Networking Guide neighbor added or removed, the router shares that information with other routers on the network at a random interval. When dev
PakBus Networking Guide 4.1 CRBasic Dataloggers (CR800, CR850, CR1000, and CR3000) PakBus settings for these dataloggers are entered with the Device
PakBus Networking Guide 4.2 CR200 Series Datalogger The CR200 Series dataloggers are programmed using the CRBasic editor. However, unlike other CRB
PakBus Networking Guide Once connected to the datalogger with the Device Configuration Utility, the PakBus address of the datalogger can be set on th
PakBus Networking Guide Since the preferred method of entering PakBus settings is with Device Configuration Utility, the next section describes some o
PakBus Networking Guide 5. PakBus Troubleshooting Tools 5.1 PakBus Graph PakBus Graph is a LoggerNet utility that graphically depicts the devices an
PakBus Networking Guide Open LogView and add a log file for viewing by choosing File | Open Log. If the log file is a low-level log containing PakBus
PakBus Networking Guide 16
Appendix A. Entering CR10X-PB PakBus Settings with a Keyboard Display If using a keyboard display to enter PakBus settings, they can be configured us
Appendix A. Entering CR10X-PB PakBus Settings with a Keyboard Display *D15 Routing Table Datalogger Memory Usage: Per node in network 16 bytes Per n
Appendix A. Entering CR10X-PB PakBus Settings with a Keyboard Display *D18 01 :xxxx Enter the interval in seconds for CSDC 7 02 :xxxx Enter the
Appendix A. Entering CR10X-PB PakBus Settings with a Keyboard Display If a “17”, for example, is typed over an existing “02” without first typing “0”
This is a blank page.
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells
PakBus Networking Guide Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat®
This is a blank page.
PakBus Networking Guide 1. Introduction PakBus® describes a proprietary family of protocols created by Campbell Scientific, Inc. for communication be
PakBus Networking Guide Beacon: A broadcast message sent over the network by a node. All PakBus devices must respond to a beacon by initiating a hel
PakBus Networking Guide Routing Table: A list of the most direct routes between nodes on the network. Routers calculate the most direct path between
PakBus Networking Guide The first and last bytes are hexidecimal “bd” characters to mark the beginning and end of a packet Link state 4 bits Desti
PakBus Networking Guide the allowed neighbor list can be set in a datalogger to limit communication between devices. Allowed neighbor lists specify n