DataView II (CD295) Dual Line Display
7. Hardware
SPECIFICATIONS
Physical
Width: 130 mm
Height: 100 mm
Depth: 30 mm
Weight: 235 g
Power Supply
8-16 Vdc (12 V nominal)
Power Consumption (at 12 Vdc)
Active with backlight – 30 mA
Active without backlight – 3 mA
Asleep – 1 mA
Communications
Physical protocol - RS232 DTE
Network protocol - PakBus
Configuration protocol - DevConfig
Environmental
Temperature
Operating -20
o
C to +55
o
C
Asleep -25
o
C to +70
o
C
Humidity
IP65 when mounted in enclosure door with supplied sealant.
General
No. of screens 30 max
Value update interval 1 – 65535 sec
Backlight period 0 – 60 secs (default 10)
Power down period 5 – 254 secs (default 120)
(255 = never sleep)
CD295 address 1 – 4094 (default 4090)
Logger address 1 – 4094 (default 1)
Description string 16 chars max
Units string 8 chars max
Decimals 0 – 6 digits after decimal