Section 5. Maintenance
5-2
Each month
Check humidity indicator card (or humidity readings from sensor).
Replace desiccant pack and tighten Heyco pressure fittings if needed.
Each Year
Check cable for rodent or environmental damage.
Replace humidity indicator card if necessary.
Every Three to Five Years
Replace 10162 Humidity Sensor (if being used).
General Maintenance
An occasional cleaning of the glass on the solar panel will improve its
efficiency.
Check sensor leads and cables for cracking, deterioration, and rodent
damage.
Check the CSBUOY-NS float, instrument housing, instrument shroud, and
cap for structural damage, poor fittings, loose fittings.