Campbell-scientific CSAT3 3-D Sonic Anemometer Instrukcja Użytkownika Strona 14

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 74
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 13
CSAT3 Three Dimensional Sonic Anemometer
2.4 Power Requirements
VOLTAGE SUPPLY: 10 to 16 Vdc
POWER:
2.4 W @ 60 Hz measurement frequency
1.2 W @ 20 Hz measurement frequency
3. Initial Setup
3.1 Factory Settings
Analog Outputs Off
Execution Parameter 10 Hz (see Section 10.3 and B.1)
Trigger Source Internal Clock (see Section 8, 9, and B.1)
SDM Address 3 (see Section 3.2, 6.1, and 10.3)
RS-232 baud rate 9600 bps (RS=0) (see Section 12 and Appendix B)
Software RTS Off (RI=0) (see Section 12 and Appendix B)
Unprompted Output Off (&=0) (see Appendix B)
The above settings can be changed with a PC, running the CSAT3 PC support
software (CSAT32.EXE), and the RS-232 cable. A copy of the CSAT3 PC support
software is available from the Campbell Scientific web site in the Support|Downloads
section.
4
Przeglądanie stron 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 73 74

Komentarze do niniejszej Instrukcji

Brak uwag