PConnect for the Palm HandheldSoftware Support forCampbell Scientific DataloggersVersion 3.4Revision: 12/09Copyright © 2001-2009Campbell Scientific,
PConnect for the Palm Handheld Step 2: Step 3: 4
PConnect for the Palm Handheld 3. Connecting Your Palm Handheld to the Datalogger 3.1 Direct Serial Connection 3.1.1 CS I/O Port Connection The mos
PConnect for the Palm Handheld The cable is connected between the PDA’s cable and the datalogger’s serial port (similar to the figure above). 3.2 RF4
PConnect for the Palm Handheld device, others have dip switches on the outside or are configured by issuing commands using a terminal emulation progra
PConnect for the Palm Handheld Select the type of datalogger to which you will be connecting and tap OK. The Edit Stations Parameter window will appe
PConnect for the Palm Handheld datalogger chosen was a mixed array datalogger, then the Datalogger field will contain other mixed array dataloggers.
PConnect for the Palm Handheld NOTE IR communication is not available for the CR200 Series dataloggers. The communications protocol for RF4xx radios
PConnect for the Palm Handheld When you are finished editing the station parameters, touch OK. You will be returned to the Stations window. PConnect
PConnect for the Palm Handheld Value button that is displayed, enter the new value, and press OK. You can change the descriptive labels for the measu
PConnect for the Palm Handheld Collect Data The Collect Data window is used to collect data from the datalogger and store it to a file on the handheld
PConnect for the Palm Handheld When the handheld is synchronized with the PC and the data file is transferred, the data will be appended to any statio
PConnect for the Palm Handheld Flags/Ports The datalogger's flags and ports can be viewed and toggled from the Flags/Ports window. All of the fl
PConnect for the Palm Handheld Terminal When Terminal is selected, the remote communications command is sent to the datalogger and it is put into a re
PConnect for the Palm Handheld Transfer Program Switch to the Transfer Program window to send a new program file to the datalogger, or to retrieve the
PConnect for the Palm Handheld File Control The File Control window is applicable only to the CR1000, CR800/850, and CR3000 dataloggers. It lets you
PConnect for the Palm Handheld Load - Displays a standard file dialog box from which to choose a file to be sent to the selected device. You can sen
PConnect for the Palm Handheld When the View Data button is touched, you will see either a list displaying the data files for that datalogger (PakBus
PConnect for the Palm Handheld derived from the file when viewing the data. To transfer an FSL file to the Palm, place the file in the C:\Campbellsci
PConnect for the Palm Handheld 4.5 Transferring Data to Your Desktop Computer Once data is collected onto your Palm handheld, you can HotSync with yo
License for Use This software is protected by United States copyright law and international copyright treaty provisions. The installation and use of t
Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel
Limited Warranty The following warranties are in effect for ninety (90) days from the date of shipment of the original purchase. These warranties are
PConnect Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab
This is a blank page.
PConnect for the Palm Handheld1 1. Introduction Welcome to PConnect for the Palm Handheld support software for Campbell Scientific's dataloggers
PConnect for the Palm Handheld PConnect does not support collection from Campbell Scientific Storage Modules or Card Storage Modules. NOTE 1.1 Conten
PConnect for the Palm Handheld After you have installed the software on your PC, follow these steps to install PConnect on your Palm device: • HotSyn