PST3/PST8PUMP AND SLUG TEST PACKAGEREVISION: 3/94COPYRIGHT (c) 1993, 1994 CAMPBELL SCIENTIFIC, INC.
SECTION 2. SOFTWARE2-2diskette 1 in floppy drive A: and enter thefollowing:installFollow the directions provided on the screen asthe installation pro
SECTION 2. SOFTWARE2-3the PST well number (y= S means all wells)TSTxxWLy.RPT Printable file with pageand column headings,page numbers andprinter form
SECTION 2. SOFTWARE2-4I. Get data from storage module toWELL.DAT1. This item allows the user to collect datafrom an SM192 or SM716 storage module.F
Connect the PST to 115 VAC via the AC adapter to "top off" the battery.After several hours or overnight, disconnect.Connect the pressure tra
Run the program PST. Select option C in the Utilities menu.Measure and note the water level in each well using a chalked tape,beeper, etc.In each well
To view a value in the *4 table, key in:*4 [location number] AORTo enter a new value into the *4 table, key in:*4 [location number] A [new value] A
6 . . . . . . . . . . . . Offset, well #1 (Engr. units) 7 . . . . . . . . . . . . Delta threshold, well #2 8 . . . . . . . . . . . . Multiplier, we
28 . . . . . . . . . . . Final logarithmic interval in seconds29 . . . . . . . . . . . Exc. code, transducer #130 . . . . . . . . . . . Exc. code,
PST3 *6 Location1 . . . . . . . . . .Level well #12 . . . . . . . . . .Level well #23 . . . . . . . . . .Level well #34 . . . . . . . . . .Locatio
Correct the offset if necessary.Ready to begin the test.Turn the recording switch to the "ON" position at the same time thepumps are turned
WARRANTY AND ASSISTANCEThe PST3/PST8 PUMP AND SLUG TEST PACKAGE is warranted by CAMPBELL SCIENTIFIC, INC. tobe free from defects in materials and work
Recorded data can be verified from the keyboard/display in *7 mode.Data retrieval should be done with a PC running PCPST.07:XXXX where XXXX is the ne
SECTION 3. TEST PROCEDURE3-91 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 3132 33 34 35 36 37 38 39 40 41 42 43 44
4-1SECTION 4. TECHNICAL DETAILS - HARDWARE4.1 STORAGE MODULEAn optional SM192 or SM716 storage modulecan be used to collect data from the PST or top
SECTION 4. TECHNICAL DETAILS 4-2TABLE 4.2-1. Keller-PSI Calibration ReportCustomer: Campbell Scientific Test Date: 07-06-92Model No: 169-110-0051 T
SECTION 4. TECHNICAL DETAILS - HARDWARE 4-3threshold is 0.25. The units are determined bythe multiplier used for the pressure transducer.In Delta s
SECTION 4. TECHNICAL DETAILS 4-4by the number of data points used eachrecording.Number Total # ofof Wells Data Points Records1 3 99662 4 74753 5 59
5-1SECTION 5. TECHNICAL DETAILS - SOFTWARE5.1 README FILEThis file contains the full text of the usersmanual for PCPST menu software. It brieflydes
SECTION 5. TECHNICAL DETAILS 5-21= EDLOG Datalogger ProgramEditor2= GRAPHTERM TerminalEmulator3= TELCOM Data CollectionProgram4= SPLIT Data Split/Me
1-1SECTION 1. HARDWAREThe PST is a complete datalogging system for pump and slug tests. The PST3 can measure up to 3wells and the PST8 up to 8 wells
SECTION 1. HARDWARE 1-2FIGURE 1-2. External Details of the PST Case
SECTION 1. HARDWARE1-3FIGURE 1-3. Using the Cable Grip to Mount the TransducerFIGURE 1-4. 12 VDC Power Options
SECTION 1. HARDWARE 1-4FIGURE 1-5. Control Panel Detail
SECTION 1. HARDWAREFIGURE 1-6. Test Configuration SwitchesMethod of Recording DataRecording TimeIf Elapsed Time has been selected it can be recorded a
After Sensor InstallationSCANThe sensors can be scanned before the test is started.No data are recorded when scanning. Set the switch toOFF when scann
2-1SECTION 2. SOFTWAREThere are 2 major software items in the PST system:• Datalogger software to operate the CR10, make the measurements and store
Komentarze do niniejszej Instrukcji