4WFB120, 4WFB350, 4WFB1K
4 Wire Full Bridge Terminal
Input Modules
Revision: 5/07
Copyright © 1996-2007
Campbell Scientific, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 ... 21 22

Podsumowanie treści

Strona 1 - Input Modules

4WFB120, 4WFB350, 4WFB1K4 Wire Full Bridge TerminalInput ModulesRevision: 5/07Copyright © 1996-2007Campbell Scientific, Inc.

Strona 2 - Warranty and Assistance

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules *Table 3 Subroutines 1: Beginning of Subroutine (P85) ;Subroutine to measure &

Strona 3 - Table of Contents

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 11: Set Active Storage Area (P80) ;Direct averaged "zero" reading 1

Strona 4

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 3: Z=X-Y (P35) ;Subtract zero reading from the 1: 1 X Loc [ mVperV

Strona 5 - 2. Specifications

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules *Table 3 Subroutines 1: Beginning of Subroutine (P85) ;Subroutine to measure &

Strona 6 - 3. Measurement Concepts

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 12: Set Active Storage Area (P80) ;Direct averaged "zero" reading 1:

Strona 7 - 5. Program Examples

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 3: Z=X-Y (P35) ;Subtract zero reading from the 1: 1 X Loc [ mVperV

Strona 8 - 5.1 Edlog

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules *Table 2 Program 01: 0.0000 Execution Interval (seconds) *Table 3 Subroutines

Strona 9

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 11: IF (X<=>F) (P89) ;Check for last pass through loop 1: 5 X Loc [

Strona 10

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 5.2.1 CR9000(X) This example program is slightly different in operation than the

Strona 11 - 5.1.2 21X

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 6. Calculation of Strain HLGVxHL or AGHR1R2R3Rg FIGURE 6-1. Strain Gage in Full

Strona 12

Warranty and Assistance The 4WFB120, 4WFB350, 4WFB1K 4 WIRE FULL BRIDGE TERMINAL INPUT MODULES are warranted by CAMPBELL SCIENTIFIC, INC. to be free

Strona 13

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules Subtracting the unstrained (zero) result from the strained result gives Vr: VVoutV

Strona 14 - 5.1.3 CR7

This is a blank page.

Strona 15

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Strona 16

4WFB120, 4WFB350, 4WFB1K Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat

Strona 17 - 5.2 CRBasic

This is a blank page.

Strona 18 - 5.2.1 CR9000(X)

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 1. Function Terminal input modules connect directly to the datalogger's inpu

Strona 19 - 6. Calculation of Strain

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules H L G 1kΩ 1kΩ Vx H L or AG H 120Ω, 350Ω, or 1kΩ FIGURE 2-1. Schemati

Strona 20

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules VVV VVrout exout ex=−(/)( /0): 3.1. ε=−412VGF Vrr() 3.2. The calculations are co

Strona 21 - This is a blank page

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 5.1 Edlog Dataloggers that use Edlog include CR510, CR10(X), 21X, and CR7. The E

Strona 22

4WFB120, 4WFB350, 4WFB1K 4 Wire Full Bridge Terminal Input Modules 3: X-Y (P35) ;Subtract zero reading from the 1: 1 X Loc [ mVperV ]