Section 14. CsiServer Control
Reference
14.1 Server Interface
14.1.1 Properties
Server.applicationWorkDir
Name
Server.applicationWorkDir As String
Description
This property gives the location where the LoggerNet server data files are
stored and must be set before starting the LoggerNet. If this property needs to
be changed after the LoggerNet server has been started, call stopServer(), set
the new location, and then call startServer().
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_BUSY
Error: The property cannot be set while a connection to
the LoggerNet server is present
Server.buildDate
Name
Server.buildDate As String
Description
This read-only property displays the build date of the LoggerNet server.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
E_CSI_FAIL
Error: Unexpected error
E_CSI_NOT_STARTED
Error: The LoggerNet server is not started